Two ferrocement cylindrical tanks of 5 cubic metres and 16 cubic metres capacity were analysed, designed, constructed and tested.
Title | Rainwater storage using ferrocement tanks in developing countries |
Publication Type | Journal Article |
Year of Publication | 1990 |
Authors | Paramasivam, P, Ong, KCG, Tan, KH, Lee, SL |
Pagination | p. 377-384: fig., tab. |
Date Published | 1990-01-01 |
Keywords | construction, design, rainwater storage, storage tanks, testing |
Abstract | Two ferrocement cylindrical tanks of 5 cubic metres and 16 cubic metres capacity were analysed, designed, constructed and tested. Based on linear elastic theory for thin shells, the magnitude of the forces acting on the tanks and the resulting reinforcement requirements were calculated. Guidelines for constructing the tanks were also developed. Two prototype tanks, which were tested over a two-year period, showed no leakage or reduction in water height. The tests confirmed that ferrocement tanks of the proposed design were suitable for rainwater storage in rural areas of developing countries. |
Notes | Includes references |
Custom 1 | 213.2 |